Pipeline and Pressure Vessels

B-TEC Pipelines & Pressure Vessel Inspection
Our experts inspect your plant, pipeline and pressure vessels to all API Code and OSHA/ASME standards.
​
B-TEC performs visual and thickness measurement inspections, mirroring OSHA 1910.119 Part J Mechanical Integrity for PSM/RMP plants and facilities. The inspections shall cover all pressure vessels, piping, and atmospheric storage tanks that handle and/or store hazardous chemicals or flammables within the facility including piping and holding tanks for fire control.
​
Our inspections include written practice development, procedure development, as well as the auditing of your plant and pipeline projects from new construction to equipment retirement.
​
Third-Party Audits
Audits of inspection records for API Code and OSHA/ASME standard compliance through objective, thorough, and reliable assessment of procedures, documentation, data etc.
​
Our Inspectors are all certified for the following:
-
Ultrasonic Flaw Detection; Ultrasonic Testing for Mechanical Integrity (OSHA PSM 1910.119)
-
Ultrasonic Shear Wave Testing of welds and weldments
-
API 510 Pressure Vessel Inspections
-
API 570 Process Pipe Inspections
-
API 653 Above Ground Storage Tank Inspection
-
Fixed and Portable Magnetic Particle Examination for welding, SCC, and parts inspection
-
Fixed and Portable Liquid Penetrant Examination for welding and parts inspection
-
Visual Examination/Weld Inspection (API 1104/ASME B31.3)
-
Radiographic film review
We will review our findings with the designated company representative and recommend solutions to remediate and keep down time to a minimum.
​
You will receive:
-
PMI Conflicts Report
-
Material Substitutions List
-
Weld Defects Report
Client will be sent a finalreport with the following:
-
Actions Item List
-
File for each Isometric Circuit
-
File for each Vessel
-
Auto CAD Drawing
-
API Visual Report
-
Corrosion Report
-
Photos
-
Deficiency Report
Pipeline & Pressure Vessel Inspection
We are available on retainer or per instance
Call us today at 719-250-6990
B-Tec sample Isometric Pipe Drawings Model

B-Tec sample Pressure Vessel Survey

.jpg)

B-TEC,LLC Completed Projects 2006-Current
(Projects are listed in order of their completion date)

Client Name: El Paso; Cheyenne Plains Gas Pipeline
Client Address: 65657 HWY 85 Carr, CO 80612
Contact person: Curtis Smith
(303) 261-4247
Type of Work: Inspection Cheyenne Plains Amine System
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
​Contact person: Calvin “Lucky” Graves
Type of Work: Inspection Latigo PSM Facility
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: Yates Petroleum
Client Address: 105 South Fourth Street Artesia, NM 88210
Type of Work: Baseline Inspection Flare System
Description: API 510; API 570 visual inspections of piping, ASME Coded Vesse;Ultrasonic Inspection of same per API 570, API 510,

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Young Storage Field Injection Wells and Ft. Morgan Plant (Fort Morgan Colorado)
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510. Follow up work on PSM plant piping and equipment.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Latigo Storage Field Injection Wells and Latigo Plant (Byers Colorado)
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510. Follow up work on PSM plant piping and equipment.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Fort Morgan Process TEG Plant (Fort Morgan, Co)
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: Yates Petroleum
Client Address: 105 South Fourth Street Artesia, NM 88210
Type of Work: Inspection Agave Dagger Draw Plant
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510, API 653

Client Name: Oneok (Des Moines Terminal)
Client Address: 4401 Vandalia Road Pleasant Hill, IA 50327
Type of Work: Inspection Des Moines Liquids Terminal
Description: API 510; API 570 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Latigo Storage Field Injection Wells
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Fort Morgan Storage Field Injection Wells
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510. Follow up work on PSM plant piping and equipment.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Young Storage PSM (Fort Morgan Colorado)
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Fort Morgan Storage Station
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: El Paso; Cheyenne Plains Gas Pipeline
Client Address: HC01 Box 84 Richfield, KS 67953
Type of Work: Inspection Fort Morgan Process TEG Plant (Fort Morgan, Co)
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: Yates Petroleum
Client Address: 105 South Fourth Street Artesia, NM 88210
Type of Work: Baseline Inspection Agave Dagger Draw Plant
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510, API 653