Pipeline and Pressure Vessels

B-TEC Pipelines & Pressure Vessel Inspection
Our experts inspect your plant, pipeline and pressure vessels to all API Code and OSHA/ASME standards.
B-TEC performs visual and thickness measurement inspections, mirroring OSHA 1910.119 Part J Mechanical Integrity for PSM/RMP plants and facilities. The inspections shall cover all pressure vessels, piping, and atmospheric storage tanks that handle and/or store hazardous chemicals or flammables within the facility including piping and holding tanks for fire control.
Our inspections include written practice development, procedure development, as well as the auditing of your plant and pipeline projects from new construction to equipment retirement.
Third-Party Audits
Audits of inspection records for API Code and OSHA/ASME standard compliance through objective, thorough, and reliable assessment of procedures, documentation, data etc.
Our Inspectors are all certified for the following:
-
Ultrasonic Flaw Detection; Ultrasonic Testing for Mechanical Integrity (OSHA PSM 1910.119)
-
Ultrasonic Shear Wave Testing of welds and weldments
-
API 510 Pressure Vessel Inspections
-
API 570 Process Pipe Inspections
-
API 653 Above Ground Storage Tank Inspection
-
Fixed and Portable Magnetic Particle Examination for welding, SCC, and parts inspection
-
Fixed and Portable Liquid Penetrant Examination for welding and parts inspection
-
Visual Examination/Weld Inspection (API 1104/ASME B31.3)
-
Radiographic film review
We will review our findings with the designated company representative and recommend solutions to remediate and keep down time to a minimum.
You will receive:
-
PMI Conflicts Report
-
Material Substitutions List
-
Weld Defects Report
Client will be sent a finalreport with the following:
-
Actions Item List
-
File for each Isometric Circuit
-
File for each Vessel
-
Auto CAD Drawing
-
API Visual Report
-
Corrosion Report
-
Photos
-
Deficiency Report
Pipeline & Pressure Vessel Inspection
We are available on retainer or per instance
Call us today at 719-250-6990
B-Tec sample Isometric Pipe Drawings Model

B-Tec sample Pressure Vessel Survey

.jpg)

B-TEC,LLC Completed Projects 2006-Current
(Projects are listed in order of their completion date)

Client Name: El Paso; Cheyenne Plains Gas Pipeline
Client Address: 65657 HWY 85 Carr, CO 80612
Contact person: Curtis Smith
(303) 261-4247
Type of Work: Inspection Cheyenne Plains Amine System
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Contact person: Calvin “Lucky” Graves
Type of Work: Inspection Latigo PSM Facility
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: Yates Petroleum
Client Address: 105 South Fourth Street Artesia, NM 88210
Type of Work: Baseline Inspection Flare System
Description: API 510; API 570 visual inspections of piping, ASME Coded Vesse;Ultrasonic Inspection of same per API 570, API 510,

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Young Storage Field Injection Wells and Ft. Morgan Plant (Fort Morgan Colorado)
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510. Follow up work on PSM plant piping and equipment.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Latigo Storage Field Injection Wells and Latigo Plant (Byers Colorado)
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510. Follow up work on PSM plant piping and equipment.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Fort Morgan Process TEG Plant (Fort Morgan, Co)
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: Yates Petroleum
Client Address: 105 South Fourth Street Artesia, NM 88210
Type of Work: Inspection Agave Dagger Draw Plant
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510, API 653

Client Name: Oneok (Des Moines Terminal)
Client Address: 4401 Vandalia Road Pleasant Hill, IA 50327
Type of Work: Inspection Des Moines Liquids Terminal
Description: API 510; API 570 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Latigo Storage Field Injection Wells
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Fort Morgan Storage Field Injection Wells
Description: API 510; API 570 visual inspections of injection well piping and ASME Coded Vessel(s); Ultrasonic Inspection of same per API 570, API 510. Follow up work on PSM plant piping and equipment.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Young Storage PSM (Fort Morgan Colorado)
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653.

Client Name: El Paso; Colorado Interstate Gas
Client Address: 24650 E. Smith Rd Aurora, CO 80019
Type of Work: Inspection Fort Morgan Storage Station
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: El Paso; Cheyenne Plains Gas Pipeline
Client Address: HC01 Box 84 Richfield, KS 67953
Type of Work: Inspection Fort Morgan Process TEG Plant (Fort Morgan, Co)
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510 and API 653

Client Name: Yates Petroleum
Client Address: 105 South Fourth Street Artesia, NM 88210
Type of Work: Baseline Inspection Agave Dagger Draw Plant
Description: API 510; API 570 and API 653 visual inspections of piping, ASME Coded Vessel(s), and Above Ground Storage Tanks; Ultrasonic Inspection of same per API 570, API 510, API 653